undefined
+
  • undefined

Copper core, cross-linked polyethylene insulated, steel tape armored polyethylene sheathed power cable

YJV22 3.6/6(7.2)kV

Structure: copper conductor/XLPE insulation/PVC outer sheath
Rated voltage: 3.6/6kV
Type:YJV
To implement the standards Applicable Standards:National standard: gb/t12706.1-2008
International Standard: International: IEC60502-1
Additional Standard: GB/T 19666-2005 General Rules for Flame Retardant and Refractory Cables
Scope of application: For transmission and distribution lines with 50 Hz AC rated voltage Uo/U of 0.6/1KV or less

  • 产品描述
  • parameter
  • Specifications
  • Describe
  • Features
  • Others
    • Commodity name: Copper core, cross-linked polyethylene insulated, steel tape armored polyethylene sheathed power cable

    YJV22 3.6/6(7.2)kV

    Structure: copper conductor/XLPE insulation/PVC outer sheath
    Rated voltage: 3.6/6kV
    Type:YJV
    To implement the standards Applicable Standards:National standard: gb/t12706.1-2008
    International Standard: International: IEC60502-1
    Additional Standard: GB/T 19666-2005 General Rules for Flame Retardant and Refractory Cables
    Scope of application: For transmission and distribution lines with 50 Hz AC rated voltage Uo/U of 0.6/1KV or less

  • YJV22 3.6/6KV 3 CORES Copper core/ XLPE insulated/ PVC sheathed/ Steel Tapes Armoured Cable

    导体截面
    Cross
    section
    绝缘厚度
    Insulation thickness
    Avg.
    近似外径
    Outer
    diameter approx.
    weight of cable approx. 最小弯曲半径
    Min.  bending radius
    载流量(空气中)
    Current ratings in air
    30℃
    载流量(埋地)
    Current ratings buried 20℃
    20℃最大直流电阻maximum DC
    resistance at 20℃
    电容
    Capacitance
    护套颜色
    Sheath
    color
    mm2 (mm) (mm) (mm) (A) (A) (Ω/km) (μF/km)
    3×25 2.5 41 492 118 150 0.73 0.24 Black Disk pack
    3×35 2.5 43.5 653 144 181 0.52 0.26 Black Disk pack
    3×50 2.5 46.5 698 172 215 0.39 0.29 Black Disk pack
    3×70 2.5 49.3 740 213 263 0.27 0.34 Black Disk pack
    3×95 2.5 54.3 815 261 315 0.19 0.35 Black Disk pack
    3×120 2.5 57.9 869 301 358 0.15 0.4 Black Disk pack
    3×150 2.5 61.7 926 341 402 0.12 0.41 Black Disk pack
    3×185 2.5 65.4 981 392 456 0.1 0.44 Black Disk pack
    3×240 2.6 70.7 1061 459 527 0.08 0.45 Black Disk pack
    3×300 2.8 77.3 1160 532 599 0.06 0.47 Black Disk pack
    3×400 3 88.1 1322 624 685 0.05 0.49 Black Disk pack

    ● Instructions for ordering:
    When ordering, the cable type, specification, length, delivery date, packing method and other necessary information shall be correctly marked.

    Model Specifications Length manner of packing Delivery date Place of delivery
    YJV22-3.6/6kV 1X250 300 m Iron and wood plate Effective until xx, 2017 1. Demander warehouse
    2. Demander's Site
    3. Self-promotion
    Note: The buyer specifies one

    ● For detailed product consultation, please inquire:

    Domestic division International division ● Mail support
    Service hotline: 400-090-9966
    Fax: 0755-6114-6789
    Working hours: 09: 00 ~ 12: 00;  13:00~19:00
    Rest days: 24/7
    Tel: 0755-6114-5028
    Fax: 0755-6113-7976
    Working hours: 09:00~18:00 (Monday to Saturday)
    Rest days: weekends and national holidays
    Dear users:
    If you have any comments or suggestions on our products, please contact us.
    E-mail:  cttcable@hotmail.com
    We will reply to your information within 2 working days.

     


  • Structural characteristics
    ● Conductor: copper conductor, type 2 conductor conforms to IEC60228
    ● Insulation: XLPE crosslinked polyethylene
    ● Sheath: PVC


    Manufacturing standard
    ● International Standard: IEC60502.1-2005
    ● National standard: GB/T12706.1-2008


    electrical specification
    ● Rated voltage Uo/U: 3.6/6(7.2)kV
    ● Maximum operating voltage: 3.6/6(7.2)kV
    ● AC withstand voltage test for finished cable: 3.6/6(7.2)kV (5 min)


    operational performance
    ● Maximum conductor temperature: 90°C
    ● Short circuit maximum core temperature (duration not exceeding 5s): 250 C.
    ● Operating temperature range: -20 to 90°C
    ● Special hoisting equipment shall be used for cable hoisting. It is strictly prohibited to hoist the cable flat or directly push off the cable from high altitude.


    Installation characteristics
    ● Minimum ambient temperature for laying: not lower than 0 C.
    ● Minimum allowable bending radius of the cable: 20 D (Note: D is the actual outer diameter of the cable)
    ● Maximum allowable pulling force: 50 N
    Minimum bending radius for cable installation

    Projects single core cable Three-core and above cables
      Unarmored Armored Unarmored Armored
    Minimum bending radius of cable during installation 20D 15D 15D 12D
    Minimum bending radius of cables close to connection boxes and terminals (but bending shall be carefully controlled, such as forming guide plates, etc.) 15D 12D 12D 10D

     

  • Delivery length transport
    ● Cables weighing less than 80kg are allowed to be delivered in loops. Each finished cable must be no less than 100m long or delivered by any length agreed by both parties.
     
    ● Allow delivery of any length according to the agreement
    ● The cable must be securely fastened during transportation to avoid damage to the cable or the disc caused by collision or overturning.
     
    ● Prevent serious bending and other mechanical damage to the cable tray.
     
    ● It is strictly forbidden to drop the cable tray with cables from the height during transportation.
     
    ● Cable hoisting uses special lifting equipment. It is strictly forbidden to lift the cable or directly drive the cable from high altitude.
    Length error Storage

    ● The length measurement error should not exceed ±0.5%

    ● The finished cable should be stored in an environment with a temperature between 0 and 40 ° C and a humidity of 85% or less. Do not expose it to direct sunlight or rain. Use proper ventilation to keep the environment dry.

    package Installation instructions
    ● The coiled or formed cable should be wound up neatly and properly packaged. Cable reels shall comply with the provisions of JB/T 8137-1999.
     
    ● The cable end should be reliably sealed. The cable end protruding from the outside of the disk should be covered with a protective cover. The extension length is less than 300mm.
     
    ● The cable package should bear a label indicating:
     
    a) Manufacturer's name and trademark
     
    b) Cable type and specifications
     
    c) rated voltage
     
    d) length (m)
     
    e) Weight (Kg)
     
    f) date of manufacture
     
    g) Standard number or certification mark
     
    h) Symbol of the correct rotation direction of the cable reel
    ● When installing, the ambient temperature should not be lower than 0 °C. If the temperature of the thermometer test environment is lower than 0 °C, the cable should be pre-heat treated before being installed.
     
    ● The bending radius during cable laying should be strictly controlled to avoid mechanical damage inside the cable.
     
    ● If a quality accident occurs in the cable laying process (such as damage to the outer sheath), it should be repaired immediately or notified to the after-sales service department of the company.