0.6/1KV XLPE insulated steel armored PVC sheathed power cable (core 1,2,3,4,5,3+2,4+1)
Number of views:
1006

0.6/1KV XLPE insulated steel armored PVC sheathed power cable (core 1,2,3,4,5,3+2,4+1)

Retail price
0.0
Market price
0.0
YJV22 0.6/1kV
Product serial number
Quantity
-
+
Stock:
Model: YJV22
Voltage class: 0.6/1kV
Structure: copper conductor/XLPE insulation/steel tape armor/PVC sheath
Insulating material: XLPE crosslinked polyethylene
Number of cable cores: 1, 2, 3, 3+1, 4, 3+2, 4+1, 5
Implementation criteria:
National standard: GB/T 12706.1-2008
International Standard: IEC60502-1
Additional Standard: GB/T 19666-2005 General Rules for Flame Retardant and Refractory Cables
Scope of application: For transmission and distribution lines with rated voltage Uo/U of 0.6/1KV and below at 50 Hz. 
It is suitable for buried laying and not suitable for laying in pipelines.
1
Specifications
Describe
Features
Others
Scan the QR code to read on your phone

Specifications and Parameters of 2-Core YJV 22 0.6/1 kV XLPE Insulated Armored Cable

芯数
No. of core
导体截面
cross-section
近似外径
Approx. diameter
mm
最小弯曲半径
min bending radius
(mm)
20℃最大导体电阻
max. DC resistance at 20
(Ω/km)

载流

(空气中)current rating in air at 30

(A)

载流量

(埋地敷设)current rating in ground at 20(A)

护套颜

Sheath

color

包装方式

Package

2 4 13.5 189 4.61 50 73 Black Plate loading
2 6 14.5 203 3.08 63 89 Black Plate loading
2 10 17.1 239 1.83 87 118 Black Plate loading
2 16 19.2 269 1.15 116 152 Black Plate loading
2 25 22.6 316 0.73 153 194 Black Plate loading
2 35 24.9 349 0.52 188 234 Black Plate loading
2 50 26.8 375 0.39 229 278 Black Plate loading
2 70 30.4 426 0.27 291 341 Black Plate loading
2 95 35.8 501 0.19 357 408 Black Plate loading
2 120 39.2 549 0.15 434 466 Black Plate loading
2 150 43.6 610 0.12 497 525 Black Plate loading
2 185 47.6 666 0.1 595 594 Black Plate loading

3-core YJV 22 0.6/1 kV XLPE insulated armored cable specifications and parameters

芯数
No. of core
导体截面
cross-section
近似外径
Approx. diameter
mm
最小弯曲半径
min bending radius
(mm)
20℃最大导体电阻
max. DC resistance at 20
(Ω/km)

载流量(空气中)current rating in air at 30

(A)

载流量(埋地敷设)current rating in ground at 20

(A)

护套颜

Sheath

color

包装方式

Package

3 4 15.2 228 4.61 37 45 Black Plate loading
3 6 16.3 244.5 3.08 46 57 Black Plate loading
3 10 18.6 279 1.83 63 77 Black Plate loading
3 16 20.7 310.5 1.15 83 100 Black Plate loading
3 25 24.2 363 0.73 112 131 Black Plate loading
3 35 26.4 396 0.52 137 158 Black Plate loading
3 50 26.8 402 0.39 163 187 Black Plate loading
3 70 32 480 0.27 211 233 Black Plate loading
3 95 35.4 531 0.19 255 277 Black Plate loading
3 120 38.8 582 0.15 298 317 Black Plate loading
3 150 43.4 651 0.12 348 358 Black Plate loading
3 185 48.5 727.5 0.1 403 403 Black Plate loading
3 240 53.5 228 0.08 480 468 Black Plate loading
3 300 57.6 244.5 0.06 549 531 Black Plate loading

4-core YJV 22 0.6/1 kV XLPE insulated armored cable specifications and parameters

芯数
No. of core
导体截面
cross-section
近似外径
Approx. diameter
mm
最小弯曲半径
min bending radius
(mm)
20℃最大导体电阻
max. DC resistance at 20
(Ω/km)

载流

(空气中)current rating in air at 30

(A)

载流

(埋地敷设)current rating in ground at 20(A)

护套颜色

Sheath

color

包装方式

Package

4 4 16.2 227 4.61 37 46 Black Plate loading
4 6 17.4 244 3.08 47 58 Black Plate loading
4 10 19.9 279 1.83 64 78 Black Plate loading
4 16 22.3 312 1.15 86 102 Black Plate loading
4 25 26.3 368 0.73 116 133 Black Plate loading
4 35 28.7 402 0.52 143 161 Black Plate loading
4 50 29.8 417 0.39 169 188 Black Plate loading
4 70 33.5 469 0.27 217 237 Black Plate loading
4 95 37.3 522 0.19 261 279 Black Plate loading
4 120 40.7 570 0.15 304 318 Black Plate loading
4 150 45.4 636 0.12 352 358 Black Plate loading
4 185 49.6 694 0.1 404 402 Black Plate loading
4 240 55 770 0.08 477 467 Black Plate loading
4 300 61.6 862 0.06 562 535 Black Plate loading

5-core YJV 22 0.6/1 kV XLPE insulated armored cable specifications and parameters

芯数
No. of core
导体截面
cross-section
近似外径
Approx. diameter
mm
最小弯曲半径
min bending radius
(mm)
20℃最大导体电阻
max. DC resistance at 20
(Ω/km)

载流

(空气中)current rating in air at 30

(A)

载流

(埋地敷设)current rating in ground at 20(A)

护套颜

Sheath

color

包装方式

Package

5 4 17.6 246 4.61 38 46 Black Plate loading
5 6 19 266 3.08 48 58 Black Plate loading
5 10 21.8 305 1.83 67 79 Black Plate loading
5 16 24.5 343 1.15 90 103 Black Plate loading
5 25 28.9 405 0.73 119 134 Black Plate loading
5 35 33 462 0.52 148 162 Black Plate loading
5 50 37.5 525 0.39 180 193 Black Plate loading
5 70 42.8 599 0.27 233 240 Black Plate loading
5 95 48.2 675 0.19 282 283 Black Plate loading
5 120 53.1 743 0.15 328 322 Black Plate loading
5 150 59.3 830 0.12 376 363 Black Plate loading
5 185 65 910 0.1 436 412 Black Plate loading
5 240 72.3 1012 0.08 520 480 Black Plate loading
5 300 79.4 1112 0.06 604 546 Black Plate loading

3+1 core YJV 22 0.6/1 kV XLPE insulated armored cable specifications and parameters


No. of core
相线导体截面
phase line cross-section
mm2
零线导体截面
neutral conductor cross-section
mm2
近似外径
Approx. diameter
mm
最小弯曲半径
min. bending radius
(mm)
20℃最大导体电阻
maximum DC resistance at 20
(Ω/km)

载流

(空气中)

current rating in air
at 30

(A)

载流

(埋地敷设)

current rating in ground at 20℃
(A)
护套颜色

sheath

color

包装方式
package
3+1core 4 2.5 15.9 223 4.61 37 45 Black Plate loading
3+1core 6 4 17.1 239 3.08 47 57 Black Plate loading
3+1core 10 6 19.3 270 1.83 64 78 Black Plate loading
3+1core 16 10 21.8 305 1.15 85 102 Black Plate loading
3+1core 25 16 25.4 356 0.73 114 132 Black Plate loading
3+1core 35 16 27.8 389 0.52 139 158 Black Plate loading
3+1core 50 25 31.1 435 0.39 172 192 Black Plate loading
3+1core 70 35 36.7 514 0.27 233 239 Black Plate loading
3+1core 95 50 40.8 571 0.19 273 286 Black Plate loading
3+1core 120 70 44.7 626 0.15 319 325 Black Plate loading
3+1core 150 70 50 700 0.12 369 365 Black Plate loading
3+1core 185 95 54.4 762 0.1 421 412 Black Plate loading
3+1core 240 120 60.1 841 0.08 503 480 Black Plate loading
3+1core 300 150 68.3 956 0.06 590 546 Black Plate loading

4+1 core YJV22 copper core XLPE insulated armored power cable specifications and parameters


No. of core
相线导体截面
phase line cross-section
mm2
零线导体截面
neutral conductor cross-section
mm2
近似外径
Approx. diameter
mm
最小弯曲半径
min. bending radius
(mm)
20℃最大导体电阻
maximum DC resistance at 20
(Ω/km)

载流

(空气中)

current rating in air
at 30

(A)

载流

(埋地敷设)

current rating in ground at 20℃
(A)
护套颜色

sheath

color

包装方式
package
4+1 core 4 2.5 17.4 244 4.61 38 46 Black Plate loading
4+1 core 6 4 18.8 263 3.08 48 58 Black Plate loading
4+1 core 10 6 21.3 298 1.83 66 79 Black Plate loading
4+1 core 16 10 24 336 1.15 88 103 Black Plate loading
4+1 core 25 16 28.1 393 0.73 117 133 Black Plate loading
4+1 core 35 16 31.9 447 0.52 145 160 Black Plate loading
4+1 core 50 25 36.2 507 0.39 177 191 Black Plate loading
4+1 core 70 35 41.1 575 0.27 228 238 Black Plate loading
4+1 core 95 50 46.4 650 0.19 277 281 Black Plate loading
4+1 core 120 70 51.5 721 0.15 324 320 Black Plate loading
4+1 core 150 70 56.3 788 0.12 369 361 Black Plate loading
4+1 core 185 95 62.2 871 0.1 428 408 Black Plate loading
4+1 core 240 120 69 966 0.08 510 475 Black Plate loading
4+1 core 300 150 76 1064 0.06 592 541 Black Plate loading
● Core Identification:
 
Two cores: red, yellow
 
Three cores: red, yellow, green or red, blue, yellow/green
 
Four cores: red, yellow, green, blue or red, yellow, green, yellow/green
 
Five cores or more: black insulated core surface printed white number
 
● Ordering Information:
 
When ordering, the necessary information such as the model, specification, length, delivery date, and packaging method of the cable should be correctly indicated.
model specification length Packing Delivery dates trading locations

YJV22-0.6/1kv

2.5 mm² 300 m Iron wood plate

Valid until xx xx, 2017

Demand warehouse
2. Demand site
3. Self-lifting
Note: A type is specified by the acquirer.


● For detailed product consultation, please inquire:

Domestic division International division ● Mail support
Service hotline: 400-090-9966
Fax: 0755-6114-6789
Working hours: 09: 00 ~ 12: 00;  13:00~19:00
Rest days: 24/7
Tel: 0755-6114-5028
Fax: 0755-6113-7976
Working hours: 09:00~18:00 (Monday to Saturday)
Rest days: weekends and national holidays
Dear users:
If you have any comments or suggestions on our products, please contact us.
E-mail:  cttcable@hotmail.com
We will reply to your information within 2 working days.

地址 : 深圳市光明新区公明办事处李松蓢社区成天泰工业园

© Shenzhen Chengtiantai Cable Industry Development Co. Ltd. All Rights Reserved

Features

Construction

● It has good mechanical properties, excellent insulation performance, large transmission capacity than oil-paper insulated cables of the same section, simple production process and favorable mass production.
 
● XLPE insulated cable has a high operating temperature (90 °C), which increases the current carrying capacity of the cable, the cable has a small bending radius, is light in weight, and is easy to maintain and install.

Conductor

● 60228 Bare copper circular stranded, according to IEC60228

Insulation

● XLPE compound

Filler

● filler

Sheath

● Compound

印字Marking

● Manufacturer, product model, voltage rating

Application range

● This product is used for AC transmission and distribution lines with a rated voltage of 1.8/3 kV and below.
 
● Can be laid indoors, in tunnels and pipes

installation:

● It can be laid indoors, in tunnels, cable trenches and pipelines. It can also be buried in loose soil. Cables can withstand certain laying and traction, but they cannot withstand mechanical external forces.
 
● Single-core cables are not allowed to be laid in magnetic pipes.

 

Structural characteristics

Use characteristics

● Conductor: Copper conductor, conductor 2 conforms to IEC60228
 
● Insulation: XLPE cross-linked polyethylene
 
● Filling: PP filling rope
 
● Inner liner: non-hygroscopic material
 
● Armored: galvanized steel tape armor
 
● Sheath: PVC
●Maximum conductor temperature: 90 ° C
 
● Short circuit maximum core temperature (duration does not exceed 5s): 250 °C.
 
● Operating temperature range: -20 to 90 ° C
 
● Cable hoisting uses special lifting equipment. It is strictly forbidden to lift the cable or directly drive the cable from high altitude.

Manufacturing Standards

Installation characteristics

● International standard: IEC60502.1-2005
 
● National standard: GB/T12706.1-2008
● Laying the minimum ambient temperature: should not be lower than 0 °C
 
● Minimum allowable bending radius of the cable: 20 D (Note: D is the actual outer diameter of the cable)
 
● Maximum allowable pull: 50 N

Electrical characteristics

电缆安装时的最小弯曲半径
● Rated voltage Uo/U: 0.6/1kV
 
● Maximum working voltage: 1.2 kV
 
● AC voltage withstand test of finished cable: 3.5 kV (5 min)
See the table below:

project

Single core cable

Three core and above cable

Unarmored

Armored

Unarmored

Armored

Minimum bend radius of the cable during installation

20D 15D 15D 12D

The minimum bend radius of the cable near the junction box and terminal (but the bend should be carefully controlled, such as using a molded guide, etc.)

15D 12D 12D 10D

 

Delivery length transport
● Cables weighing less than 80kg are allowed to be delivered in loops. Each finished cable must be no less than 100m long or delivered by any length agreed by both parties.
 
● Allow delivery of any length according to the agreement
● The cable must be securely fastened during transportation to avoid damage to the cable or the disc caused by collision or overturning.
 
● Prevent serious bending and other mechanical damage to the cable tray.
 
● It is strictly forbidden to drop the cable tray with cables from the height during transportation.
 
● Cable hoisting uses special lifting equipment. It is strictly forbidden to lift the cable or directly drive the cable from high altitude.
Length error Storage

● The length measurement error should not exceed ±0.5%

● The finished cable should be stored in an environment with a temperature between 0 and 40 ° C and a humidity of 85% or less. Do not expose it to direct sunlight or rain. Use proper ventilation to keep the environment dry.

package Installation instructions
● The coiled or formed cable should be wound up neatly and properly packaged. Cable reels shall comply with the provisions of JB/T 8137-1999.
 
● The cable end should be reliably sealed. The cable end protruding from the outside of the disk should be covered with a protective cover. The extension length is less than 300mm.
 
● The cable package should bear a label indicating:
 
a) Manufacturer's name and trademark
 
b) Cable type and specifications
 
c) rated voltage
 
d) length (m)
 
e) Weight (Kg)
 
f) date of manufacture
 
g) Standard number or certification mark
 
h) Symbol of the correct rotation direction of the cable reel
● When installing, the ambient temperature should not be lower than 0 °C. If the temperature of the thermometer test environment is lower than 0 °C, the cable should be pre-heat treated before being installed.
 
● The bending radius during cable laying should be strictly controlled to avoid mechanical damage inside the cable.
 
● If a quality accident occurs in the cable laying process (such as damage to the outer sheath), it should be repaired immediately or notified to the after-sales service department of the company.

 

Related products

微信

Tel:  86-755-86909666

 

Working hour:8:00 am~6:00 pm

  • E-mail: cttcable@gmail.com
  • No.130 Jingsong 3rd road, Lisonglang Community, Gongming Street, Guangming District, Shenzhen, Guangdong, China, 518000
Username used for comment:
客户留言
Description:
©2010-2019 Shenzhen Chengtiantai Cable Industrial Development Co.,Ltd. 粤ICP备05044349号